title: "Usage and function of \"Duress Entry\" code - Roger"
description: "Roger - lider branży zabezpieczeń oferujący systemy kontroli dostępu, rejestracji czasu pracy, rejestracji pracy wartowników. Zapraszamy!"
url: "https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/racs-4-system/pr-master-software/usage-and-function-of-duress-entry-code"
date: "2026-06-27T13:38:11+00:00"
language: "en-GB"
---

#  Usage and function of "Duress Entry" code

- [Download](https://www.roger.pl/en/support/technical-support/download)
- [Newsletter](https://www.roger.pl/en/support/technical-support/newsletter)
- [News](https://www.roger.pl/en/support/technical-support/news)
- [Quick Start Guide](https://www.roger.pl/en/support/technical-support/quick-start-guide)
- [Remote Technical Support](https://www.roger.pl/en/support/technical-support/remote-technical-support)
- [FAQ - Frequently Asked Questions](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions)
    - [Access Control](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control)
        - [RACS 5 System](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/racs-5-system)
        - [RACS 4 System](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/racs-4-system)
            - [PR Master Software](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/racs-4-system/pr-master-software)
            - [Access Controllers](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/racs-4-system/access-controllers)
            - [System Devices](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/racs-4-system/system-devices)
        - [Access Terminals](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/access-terminals)
        - [Auxiliary Equipment](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/auxiliary-equipment)
        - [Transponders](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/transponders)
        - [Electronic Code Locks](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/electronic-code-locks)
    - [Time &amp; Attendance](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/time-attendance)
    - [Guard Tour System](https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-guard-tour-system)

**Description:
I have programmed a user with PIN code for example 7777. Codes 7776 and 7778 open door as well as 7777. Why is that happening? How to disable these codes?**

**Solution:**

If the user enters a code, which differs from its originate form by one (plus or minus one), the reader interprets it as an duress code entry. When Duress entry occur the \[DURESS entry\] event is sent to system HOST and an \[FORCED ENTRY\] alarm on ALARM output is activated.

For proper reorganization of Duress Entry, the codes of individual users should differ one from each other at least by a value of +/- \[2\] in the last digit.

There is no possibility to disable "Duress Entry" function. However it is possible to enable option, which allows to define PIN codes which differ by +/- \[1\] on last position. In order to do this in PR Master software choose: *Tools* -&gt; *Options* -&gt; *Misc* bookmark  *-&gt; Allow for PIN codes which differ by +/-1 on last position.* Also one can disable Duress Entry signalization on advanced PRxx2 series controllers.

## Schema

```json
{ "@context": "https://schema.org", "@type": "BreadcrumbList", "itemListElement": [ { "@type": "ListItem", "position": 1, "name": "Start", "item": "https://www.roger.pl/en" }, { "@type": "ListItem", "position": 2, "name": "Support", "item": "https://www.roger.pl/en/support" }, { "@type": "ListItem", "position": 3, "name": "Technical Support", "item": "https://www.roger.pl/en/support/technical-support" }, { "@type": "ListItem", "position": 4, "name": "FAQ - Frequently Asked Questions", "item": "https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions" }, { "@type": "ListItem", "position": 5, "name": "Access Control", "item": "https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control" }, { "@type": "ListItem", "position": 6, "name": "RACS 4 System", "item": "https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/racs-4-system" }, { "@type": "ListItem", "position": 7, "name": "PR Master Software", "item": "https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/racs-4-system/pr-master-software" }, { "@type": "ListItem", "position": 8, "name": "Usage and function of "Duress Entry" code", "item": "https://www.roger.pl/en/support/technical-support/faq-frequently-asked-questions/faq-access-control/racs-4-system/pr-master-software/usage-and-function-of-duress-entry-code" } ] }
```