Firmware for Advanced Access Controllers PRxx2 series
Copyright Roger Sp.j.
========================================================================



PRxx2 v.x.18.06.1947	06.11.2015
----------------------------------
1. Modified firmware number format i.e. x.yy.zz.vvvv where x - hardware compatibility, yy - functional compatibility, zz - release number and vvvv - compilation number
2. Added renewable login limits
3. Improved immunity of readers for external interferances
4. Modified reset procedures
5. Added support for PR402DR-12VDC, PR602LCD-DT, PR312EM and PR312MF controllers
6. Added support for PP500 Siemens readers
7. Added [74] output function enabling external reader antenna switching
8. Added support for HRT82FK function key panel
9. Added [92] output function and option enabling user access denying until temporary T&A Mode is selected
10. Corrected commands for remote arming/disarming
11. Corrected [33] and [34] output functions
12. Corrected max amount of users in room for local APB
13. Corrected global APB
14. Corrected emulation of function keys by means of controller numeric keypad


PRxx2 v.2.16.1665	16.08.2012
----------------------------------

1. Added suppor for PR102DR controller
2. Added support for IMAX overload line in PR402DR and PR102Dr controllers
3. Corrected restoring of previous modes/states and flags after restart and configuration upload


PRxx2 v.2.14.1629	21.12.2011
----------------------------------
1. Corrected the reset procedure of PR402-BRD, PR302, PR602LCD controllers
2. Corrected the option: Disable Forced Entry event
3. Corrected the function of output line [22]: Postponed auto-arming delay in progress
4. Added the command: Undelete event buffer on controller - PRMaster 4.4.6 software required.
5. Removed the error related to controller ID set by means of jumpers.
6. Removed relay switching after restart of PR402DR controller


PRxx2 v.2.12.1621	30.08.2011
----------------------------------
1. Corrected the command "Quick user update" available in PR Master software


PRxx2 v.2.10.1615	11.07.2011
----------------------------------
1. Corrected the option "Incoming auto-arming in progress signalling time" 
2. Added the event concerning incorrect prox. card/PIN in "Card and PIN" identification mode
3. Corrected the error related to Facility Code
4. The option "Delay before door is opened" limited to door in Normal mode
5. Removed the error related to XM-8 expander (elevator control)
6. Corrected functions related to monitoring of inputs IN5..IN8 in PR402DR controller and inputs IN14..IN15 in XM-2 extension module
7. Removed the error in "Quick User Update" function


PRxx2 v.2.07.1604	22.3.2011
------------------------------
1. New controllers added, i.e. PR402DR dedicated for installation on DIN 35mm rail and PR402DR-BRD, which is PCB module without any enclosure (required PR Master software ver. 4.4.1.586 or higher)
2. Corrected the option: "Enable # key to operate alternatively as Door Bell or Exit Button" for Terminal ID0
3. Corrected schedule after 4:00 pm in H4 day (holiday)
4. Improved time accuracy for arming, auto-arming
5. Corrected incoming auto-arming signalling before midnight
6. New terminal available - [29]: HID Wiegand (37/56 bits) + PIN Galaxy 26 bit
7. Increased number (max. 100) of available T&A mode messages to be displayed at PR602 LCD

PRxx2 v.2.04.1596	20.12.2010
------------------------------
1. New option [45] for input and function key added. This option switches momentary built-in terminal (ID=1) to emulate external terminal (ID=0). Function is available on PR302 and PR602LCD controllers.

PRxx2 v.2.04.1557	26.7.2010
------------------------------
1. Operation with Wiegand type readers improved
2. Problem when triggering extra delay before auto-arming corrected

PRxx2 v.2.04.1553	28.5.2010
------------------------------
1. Error corrected: problem with output line configured to function [47]: Entry button.

PRxx2 v.2.04.1552	16.4.2010
------------------------------
1. Error when selecting T&A mode from external reader (ID0) corrected.
2. LCD dispaly backlight mechanism corrected (PR602LCD).
3. New function: controller can designate randoom user for personal check.
4. When logging on external reader (ID0) PR602LCD displays T&A mode of the external reader. Previously, LCD dispaly always presented T&A mode for ID1 terminal no matter on which terminal user has been logged.

PRxx2 v.2.03.1540	24.1.2010
------------------------------
1. Increased immunity to external magnetic interferences which caused reading of the cards from the "air".

PRxx2 v.2.03.1539	9.1.2010
------------------------------
1. Output line control logic corrected. This modification removes period of few seconds (usualy 3-6s) when output lines returned to OFF state which occured between moment when new settings has been uploaded to the controller and the moment when new output states has been initialized accoroding to new settings.