#  MCX16-UZ  Expander to Integrate Clex System Locks

The MCX16-UZ I/O expander enables use of Clex (Uhlmann &amp; Zacher) wireless locks as access terminals in RACS 5 system.

 ![MCX16-UZ](https://www.roger.pl/templates/yootheme/cache/7c/mc16-galeria-7c689815.png)MCX16-UZ

 ![MCX16-UZ](https://www.roger.pl/templates/yootheme/cache/54/mc16-bok-galeria-54bdbe83.png)MCX16-UZ

 ![MCX16-UZ DIMENSIONS](https://www.roger.pl/templates/yootheme/cache/62/mc16-rys-galeria-620025d4.png)MCX16-UZ DIMENSIONS

 [](#)

 [](#)

- [![MCX16-UZ](https://www.roger.pl/templates/yootheme/cache/26/mc16-galeria-2668029b.png)](#)
- [![MCX16-UZ](https://www.roger.pl/templates/yootheme/cache/ea/mc16-bok-galeria-ea91638e.png)](#)

- [![MCX16-UZ DIMENSIONS](https://www.roger.pl/templates/yootheme/cache/a4/mc16-rys-galeria-a407c76d.png)](#)

 [ ](https://www.roger.pl/index.php?option=com_content&view=category&id=109&lang=en-GB)

 MCX16-UZ

- [About](#o-produkcie)
- [Versions](#dostepne-wersje)

- [Download](#do-pobrania)
- [Related products](#powiazane)

- [Quick links](#linki)

###  About

The MCX16-UZ I/O expander enables use of Clex (Uhlmann &amp; Zacher) wireless locks as access terminals in [RACS 5 system](https://www.roger.pl/index.php?Itemid=419&lang=en).

MCX16-UZ operates as hardware interface for communication of Clex locks with MC16 access controller. The expander communicates with the MC16 controller using RS485-1 bus and with Clex public online system using RS485-2 bus. MCX16-UZ offers its input and output lines for use in RACS 5 system.

---

###  Features

- interface for 8 Clex (Uhlmann &amp; Zacher) wireless locks
- 8 inputs NO/NC
- 6 transistor outputs 12 V/1.0 A
- 2 relay outputs NO/NC 30 V/1.5 A DC/AC
- power outputs 13.8 V/1.0 A and 13.8 V/0.2 A
- 24 VDC, 18 VAC or 12 VDC power supply
- battery charging with 0.3 A current
- protection against full battery discharge
- reporting of power supply status to access controller
- installation on DIN rail or flat surface
- module dimensions (height x width x depth): 72.0 x 175.0 x 30.0 mm
- CE; RoHS

---

###  Versions

**MCX16-UZ-2**
I/O expander with the interface to wireless locks of the Clex system by Uhlmann &amp; Zacher, license for 2 wireless locks

---

**MCX16-UZ-4**
I/O expander with the interface to wireless locks of the Clex system by Uhlmann &amp; Zacher, license for 4 wireless locks

---

**MCX16-UZ-8**
I/O expander with the interface to wireless locks of the Clex system by Uhlmann &amp; Zacher, license for 8 wireless locks

---

**MCX16-UZ-LIC-1**
License extension for 1 Clex wireless lock by Uhlmann &amp; Zacher

---

[WHERE TO BUY](https://www.roger.pl/index.php?option=com_storelocator&view=map&Itemid=525&lang=en)

---

###  Download

[ pdfMCX16-UZ Installation Manual(233 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3689-mcx16-uz-operating-manual&category_slug=manuals&Itemid=642&lang=en)

[ pdfAN056 Integration with Clex (Uhlmann &amp; Zacher) Wireless Locks(543 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3678-integration-with-clex-uhlmann-zacher-wireless-locks&category_slug=application-notes-for-racs-5-v2-system&Itemid=810&lang=en)

[ pdfMCX16-UZ Data Sheet(601 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3687-mcx16-uz-data-sheet&category_slug=data-sheets&Itemid=646&lang=en)

[ pdfMCX16-UZ Declaration of Conformity EC(108 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3707-mcx16-uz-declaration-of-conformity-ec&category_slug=certificates&Itemid=649&lang=en)

---

###  Related products

 [ ![](https://www.roger.pl/templates/yootheme/cache/61/mc16-intro-614f01ac.png)

###  MC16-AZC

Advanced Access Zone Controller

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=392:mc16-azc-advanced-access-zone-controller&catid=107&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/f7/mcx4d-intro-f7b74abc.png)

###  MCX4D

Door Expander

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=412:mcx4d-door-expander&catid=109&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/a1/me-40-intro-a19bb244.png)

###  Metal Enclosures

of the RACS 5 System

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=691:metal-enclosures&catid=104&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/c1/ps4d-intro-c1bc6518.png)

###  Power Supplies

of the RACS 5 System

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=692:power-supplies&catid=104&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/b5/roger-vdm-intro-b5beda13.png)

###  RogerVDM

Windows Application for RACS 5 Device Setup and Maintenance

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=378:rogervdm-windows-application-for-racs-5-device-setup-and-maintenance&catid=105&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/91/viso-intro-910186aa.png)

###  VISO EX

Application for RACS 5 System Management and Configuration

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=824:viso-ex-application-for-racs-5-system-management-and-configuration&catid=105&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/7f/viso-st-intro-7fb635cc.png)

###  VISO ST

Application for RACS 5 System Management and Configuration

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=374:viso-st-application-for-racs-5-system-management-and-configuration&catid=105&lang=en-GB)

---

###  Quick links

 [ ![](https://www.roger.pl/images/ikony-oferta/wsparcie%201.svg)###  Inquiry

Więcej

 ](mailto:support@roger.pl)

 [ ![](https://www.roger.pl/images/ikony-oferta/gdzie-kupic.svg)###  WHERE TO BUY

Więcej

 ](https://www.roger.pl/index.php?Itemid=525)

 [ ![](https://www.roger.pl/images/ikony-oferta/cennik.svg)###  Download

Więcej

 ](https://www.roger.pl/index.php?Itemid=544)

 [ ![](https://www.roger.pl/images/ikony-oferta/kontakt.svg)###  Contact us

Więcej

 ](https://www.roger.pl/index.php?Itemid=523)

## Schema

```json
{ "@context": "https://schema.org", "@type": "BreadcrumbList", "itemListElement": [ { "@type": "ListItem", "position": 1, "name": "Start", "item": "https://www.roger.pl/en" }, { "@type": "ListItem", "position": 2, "name": "Products", "item": "https://www.roger.pl/en/products" }, { "@type": "ListItem", "position": 3, "name": "RACS 5 Access Control System", "item": "https://www.roger.pl/en/products/racs-5-access-control-system" }, { "@type": "ListItem", "position": 4, "name": "Expanders", "item": "https://www.roger.pl/en/products/racs-5-access-control-system/expanders" }, { "@type": "ListItem", "position": 5, "name": "MCX16-UZ | Expander to Integrate Clex System Locks", "item": "https://www.roger.pl/en/products/racs-5-access-control-system/expanders/mcx16-uz-expander-to-integrate-clex-system-locks" } ] }
```

```json
{ "@context": "https://schema.org", "@type": "Product", "name": "MCX16-UZ | Expander to Integrate Clex System Locks", "image": "https://www.roger.pl/", "description": "The MCX16-UZ I/O expander enables use of Clex (Uhlmann &amp; Zacher) wireless locks as access terminals in RACS 5 system." }
```