title: "MC16-EVC | Conventional Elevator Access Controller - Roger"
description: "Roger - lider branży zabezpieczeń oferujący systemy kontroli dostępu, rejestracji czasu pracy, rejestracji pracy wartowników. Zapraszamy!"
url: "https://www.roger.pl/en/products/racs-5-access-control-system/access-controllers/mc16-evc-conventional-elevator-access-controller"
date: "2026-06-27T17:19:30+00:00"
language: "en-GB"
---

#  MC16-EVC  Conventional Elevator Access Controller

MC16-EVC controller is designed to work with classic elevator systems where the floor is selected by changing the state of electrical contact associated with the floor button.

 ![](https://www.roger.pl/templates/yootheme/cache/7c/mc16-galeria-7c689815.png)

 ![](https://www.roger.pl/templates/yootheme/cache/54/mc16-bok-galeria-54bdbe83.png)

 ![](https://www.roger.pl/templates/yootheme/cache/62/mc16-rys-galeria-620025d4.png)

 [](#)

 [](#)

- [![](https://www.roger.pl/templates/yootheme/cache/26/mc16-galeria-2668029b.png)](#)
- [![](https://www.roger.pl/templates/yootheme/cache/ea/mc16-bok-galeria-ea91638e.png)](#)

- [![](https://www.roger.pl/templates/yootheme/cache/a4/mc16-rys-galeria-a407c76d.png)](#)

 [ ](https://www.roger.pl/index.php?option=com_content&view=category&id=107&lang=en-GB)

 MC16-EVC

- [About](#o-produkcie)
- [Versions](#dostepne-wersje)

- [Download](#do-pobrania)
- [Related products](#powiazane)

- [Quick links](#linki)

###  About

MC16-EVC controller is designed to work with classic elevator systems where the floor is selected by changing the state of electrical contact associated with the floor button.

 In the access control concept used in the MC16-EVC controller, the user must first identify at the reader installed in the elevator to select the floor and then the controller activates a set of output lines that unlock the floors to which the given user has access.

The authorizations for individual floors can be defined using time schedules and calendars, and there is also the option to unlock buttons to cancel the requirement for user identification. The outputs for buttons unlocking can be located on any I/O expanders connected to the controller, however the most suitable for this purpose is the MCX8 expander offering eight relay outputs with isolated NO/NC contacts. User identification can be carried out on any MCT series reader, PRT series reader or compatible Wiegand interface reader. The controller supports one elevator with 64 floors and up to 8,000 users.

As with other MC16 series controllers, communication with the VISO management application is encrypted and takes place via LAN/WAN network. The conventional elevators are supported in VISO ST management software and there is not limit in terms of the number of lifts serviced in the system.

---

###  Features

 | Parameter | MC16-EVC-8 | MC16-EVC-16 | MC16-EVC-32 | MC16-EVC-64 |
|---|---|---|---|---|
| floors | 8 | 16 | 32 | 64 |
| access points | 1 | 1 | 1 | 1 |
| access terminals | 4 | 4 | 4 | 4 |
| access zones | 0 | 0 | 0 | 0 |
| alarm zones | 0 | 0 | 0 | 0 |
| power supplies | 2 | 4 | 8 | 16 |
| automation nodes | 2 | 2 | 2 | 2 |
| control commands | 4 | 4 | 4 | 4 |
| inputs | 8 | 8 | 8 | 8 |
| outputs | 16 | 32 | 64 | 128 |
| function keys | 8 | 8 | 8 | 8 |
| access credentials | 8192 | 8192 | 8192 | 8192 |
| access doors per access points | 8 | 16 | 32 | 64 |

---

###  Versions

**MC16-EVC-8**
Conventional elevator access controller; 8 floors license

---

**MC16-EVC-16**
Conventional elevator access controller; 16 floors license

---

**MC16-EVC-32**
Conventional elevator access controller; 32 floors license

---

**MC16-EVC-64**
Conventional elevator access controller; 64 floors license

---

[WHERE TO BUY](https://www.roger.pl/index.php?option=com_storelocator&view=map&Itemid=525&lang=en)

---

###  Download

[ pdfRACS 5 Certificate PN-EN60839 - grade IV(1.12 MB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3929-racs-5-certificate-pn-en60839-grade-iv&category_slug=declarations-of-conformity&Itemid=649&lang=en)

[ pdfMC16 Installation Manual(368 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3596-mc16-installation-manual-1&category_slug=manuals&Itemid=642&lang=en)
The manual refers to controllers with firmware v1.7.4 and higher

[ pdfMC16 Operating Manual(1.54 MB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3597-mc16-operating-manual-1&category_slug=manuals&Itemid=642&lang=en)
The manual refers to controllers with firmware v1.7.4 and higher

[ pdfMC16-EVC Data Sheet(758 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3100-mc16-evc-data-sheet&category_slug=data-sheets&Itemid=646&lang=en)

[ pdfMC16 Declaration of Conformity EC(104 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=2102-mc16-declaration-of-conformity-ec&category_slug=certificates&Itemid=649&lang=en)

[ pdfMC16 Declaration PN-EN50133(117 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=2750-mc16-declaration-pn-en50133&category_slug=certificates&Itemid=649&lang=en)

[ ArchiveMC16 Firmware v1.1.1.208(503 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=2524-mc16-firmware-v1-1-1-208&category_slug=firmware&Itemid=651&lang=en)

[ ArchiveMC16 Firmware v1.7.4.666(533 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3681-mc16-firmware-1&category_slug=firmware&Itemid=651&lang=en)
**Note!** Updating the firmware to version 1.7.4 requires a new controller license file. In version 1.7.4.647, support for alarm functions in the controller's Alarm Zone has been removed!

---

###  Related products

 [ ![](https://www.roger.pl/templates/yootheme/cache/b8/mcx8-brd-intro-b8be3099.png)

###  MCX8-BRD

I/O Expander

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=411:mcx8-brd-i-o-expander&catid=109&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/a1/me-40-intro-a19bb244.png)

###  Metal Enclosures

of the RACS 5 System

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=691:metal-enclosures&catid=104&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/c1/ps4d-intro-c1bc6518.png)

###  Power Supplies

of the RACS 5 System

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=692:power-supplies&catid=104&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/eb/mct82m-intro-ebb1e754.png)

###  Proximity Readers

of the RACS 5 System

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=695:proximity-readers&catid=104&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/b5/roger-vdm-intro-b5beda13.png)

###  RogerVDM

Windows Application for RACS 5 Device Setup and Maintenance

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=378:rogervdm-windows-application-for-racs-5-device-setup-and-maintenance&catid=105&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/7f/viso-st-intro-7fb635cc.png)

###  VISO ST

Application for RACS 5 System Management and Configuration

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=374:viso-st-application-for-racs-5-system-management-and-configuration&catid=105&lang=en-GB)

---

###  Quick links

 [ ![](https://www.roger.pl/images/ikony-oferta/wsparcie%201.svg)###  Inquiry

Więcej

 ](mailto:support@roger.pl)

 [ ![](https://www.roger.pl/images/ikony-oferta/gdzie-kupic.svg)###  WHERE TO BUY

Więcej

 ](https://www.roger.pl/index.php?Itemid=525)

 [ ![](https://www.roger.pl/images/ikony-oferta/cennik.svg)###  Download

Więcej

 ](https://www.roger.pl/index.php?Itemid=544)

 [ ![](https://www.roger.pl/images/ikony-oferta/kontakt.svg)###  Contact us

Więcej

 ](https://www.roger.pl/index.php?Itemid=523)

## Schema

```json
{ "@context": "https://schema.org", "@type": "BreadcrumbList", "itemListElement": [ { "@type": "ListItem", "position": 1, "name": "Start", "item": "https://www.roger.pl/en" }, { "@type": "ListItem", "position": 2, "name": "Products", "item": "https://www.roger.pl/en/products" }, { "@type": "ListItem", "position": 3, "name": "RACS 5 Access Control System", "item": "https://www.roger.pl/en/products/racs-5-access-control-system" }, { "@type": "ListItem", "position": 4, "name": "Access Controllers", "item": "https://www.roger.pl/en/products/racs-5-access-control-system/access-controllers" }, { "@type": "ListItem", "position": 5, "name": "MC16-EVC | Conventional Elevator Access Controller", "item": "https://www.roger.pl/en/products/racs-5-access-control-system/access-controllers/mc16-evc-conventional-elevator-access-controller" } ] }
```

```json
{ "@context": "https://schema.org", "@type": "Product", "name": "MC16-EVC | Conventional Elevator Access Controller", "image": "https://www.roger.pl/", "description": "MC16-EVC controller is designed to work with classic elevator systems where the floor is selected by changing the state of electrical contact associated with the floor button." }
```