#  MC16-AZC  Advanced Access Zone Controller

The MC16-AZC controller is a variation of the MC16 standard access controller (RACS 5 system) in which one of the access zones may be subject to additional, advanced access control mechanisms.

 ![](https://www.roger.pl/templates/yootheme/cache/7c/mc16-galeria-7c689815.png)

 ![](https://www.roger.pl/templates/yootheme/cache/54/mc16-bok-galeria-54bdbe83.png)

 ![](https://www.roger.pl/templates/yootheme/cache/62/mc16-rys-galeria-620025d4.png)

 [](#)

 [](#)

- [![](https://www.roger.pl/templates/yootheme/cache/26/mc16-galeria-2668029b.png)](#)
- [![](https://www.roger.pl/templates/yootheme/cache/ea/mc16-bok-galeria-ea91638e.png)](#)

- [![](https://www.roger.pl/templates/yootheme/cache/a4/mc16-rys-galeria-a407c76d.png)](#)

 [ ](https://www.roger.pl/index.php?option=com_content&view=category&id=107&lang=en-GB)

 MC16-AZC

- [About](#o-produkcie)
- [Versions](#dostepne-wersje)

- [Download](#do-pobrania)
- [Related products](#powiazane)

- [Quick links](#linki)

###  About

The MC16-AZC controller is a variation of the MC16 standard access controller (RACS 5 system) in which one of the access zones may be subject to additional, advanced access control mechanisms.

These mechanisms include the limit of entries, the limit of days with entries, the limit of days without entries, and the group attendance limits.

The limit of entries determines the number of entries to the zone. The limit of days with access determines the number of days during which the access can be granted, however these days do not have to compose a continuous time-period. Both mentioned mechanisms are usually used to control access to places where access is subject to fees (e.g., recreational facilities) or there is a need to restrict the number of entries (e.g., one-time access for the car driver who delivers goods). The limit of days without entries determines the number of consecutive days in which the user has not entered the zone and, after reaching, whose access right will be automatically blocked. This function can be used to automatically block access in case the user loses or doesn’t return the identifier to the system administrator, even though he or she is no longer operating in the building.

User group attendance limit disables access for users which belong to a particular group that reached its attendance limit, however access can be restored if the number of the particular group drops below the limit. Along with optional LPR cameras, also served in RACS 5 system, this functionality is usually used to organize access control for car parks shared by many tenants of an office building.

All limits discussed above can be defined individually for each system user. Actual limit values can be read and amended at any time by the system managing software. The MC16-AZC controller is hardware compatible with other controllers of the MC16 family and can support up to 16 doors/gates, however only one of the controlled zones is being subject to the advanced access control functions discussed earlier.

---

###  Features

 | Parameter | AZC-1 | AZC-2 | AZC-3 | AZC-4 | AZC-5 | AZC-6 | AZC-7 | AZC-8 | AZC-9 | AZC-10 | AZC-11 | AZC-12 | AZC-13 | AZC-14 | AZC-15 | AZC-16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| access doors | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
| access points | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
| access terminals | 4 | 8 | 12 | 16 | 20 | 24 | 28 | 32 | 36 | 40 | 44 | 48 | 52 | 56 | 60 | 64 |
| access zones | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
| alarm zones | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
| power supplies | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
| local commands | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 |
| inputs | 8 | 12 | 18 | 24 | 30 | 36 | 42 | 48 | 54 | 60 | 66 | 72 | 78 | 84 | 90 | 96 |
| outputs | 8 | 8 | 12 | 16 | 20 | 24 | 28 | 32 | 36 | 40 | 44 | 48 | 52 | 56 | 60 | 64 |
| function keys | 4 | 8 | 12 | 16 | 20 | 24 | 28 | 32 | 64 | 40 | 44 | 48 | 52 | 56 | 60 | 64 |
| access credentials | 8192 |
| access doors per access point | 1 |

---

###  Versions

**MC16-AZC-1**
Parking access controller for 1 door

---

**MC16-AZC-2**
Parking access controller for 2 doors

---

**MC16-AZC-3**
Parking access controller for 3 doors

---

**MC16-AZC-4**
Parking access controller for 4 doors

---

**MC16-AZC-N**
Parking access controller; N-door license (N=1-16)

---

**MC16-AZC-LIC-1**
1-door license extension for MC16-AZC access controller

---

[WHERE TO BUY](https://www.roger.pl/index.php?option=com_storelocator&view=map&Itemid=525&lang=en)

---

###  Download

[ pdfRACS 5 Certificate PN-EN60839 - grade IV(1.12 MB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3929-racs-5-certificate-pn-en60839-grade-iv&category_slug=declarations-of-conformity&Itemid=649&lang=en)

[ pdfMC16 Installation Manual(469 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=2326-mc16-installation-manual&category_slug=manuals&Itemid=642&lang=en)

[ pdfMC16 Operating Manual(1.23 MB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3140-mc16-operating-manual&category_slug=manuals&Itemid=642&lang=en)

[ pdfAN028 License Plate Recognition Cameras(857 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=2897-an028-license-plate-recognition-cameras&category_slug=application-notes-for-racs-5-system&Itemid=643&lang=en)

[ pdfKR004 Car Park Access Control(474 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=2983-kr004-car-park-access-control&category_slug=system-solutions&Itemid=645&lang=en)

[ pdfKR004 Car Park Access Control (Danish)(521 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3308-kr004-car-park-access-control-danish&category_slug=system-solutions&Itemid=645&lang=en)

[ pdfMC16-AZC Data Sheet(750 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=2936-mc16-azc-data-sheet&category_slug=data-sheets&Itemid=544&lang=en)

[ pdfMC16 Declaration of Conformity EC(104 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=2102-mc16-declaration-of-conformity-ec&category_slug=certificates&Itemid=649&lang=en)

[ pdfMC16 Declaration PN-EN50133(117 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=2750-mc16-declaration-pn-en50133&category_slug=certificates&Itemid=649&lang=en)

[ ArchiveMC16-AZC Firmware v1.7.4.666(532 KB)](https://www.roger.pl/index.php?option=com_docman&view=document&alias=3682-mc16-azc-firmware-1&category_slug=firmware&Itemid=651&lang=en)
**Note!** The firmware is dedicated to the MC16-AZC controller only. In version 1.7.4.647, support for alarm functions in the controller's Alarm Zone has been removed!

---

###  Related products

 [ ![](https://www.roger.pl/templates/yootheme/cache/b7/mct80m-ble-intro-b7ee3c9b.png)

###  MCT80M-BLE

Access Terminal

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=408:mct80m-ble-access-terminal&catid=108&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/a1/me-40-intro-a19bb244.png)

###  Metal Enclosures

of the RACS 5 System

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=691:metal-enclosures&catid=104&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/c1/ps4d-intro-c1bc6518.png)

###  Power Supplies

of the RACS 5 System

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=692:power-supplies&catid=104&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/67/roger-mobile-key-intro-linear-6789bc8d.png)

###  Roger Mobile Key

Mobile Application for RACS 5 System User Identification

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=379:roger-mobile-key-mobile-application-for-racs-5-system-user-identification&catid=105&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/b5/roger-vdm-intro-b5beda13.png)

###  RogerVDM

Windows Application for RACS 5 Device Setup and Maintenance

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=378:rogervdm-windows-application-for-racs-5-device-setup-and-maintenance&catid=105&lang=en-GB)

 [ ![](https://www.roger.pl/templates/yootheme/cache/7f/viso-st-intro-7fb635cc.png)

###  VISO ST

Application for RACS 5 System Management and Configuration

→

 ](https://www.roger.pl/index.php?option=com_content&view=article&id=374:viso-st-application-for-racs-5-system-management-and-configuration&catid=105&lang=en-GB)

---

###  Quick links

 [ ![](https://www.roger.pl/images/ikony-oferta/wsparcie%201.svg)###  Inquiry

Więcej

 ](mailto:support@roger.pl)

 [ ![](https://www.roger.pl/images/ikony-oferta/gdzie-kupic.svg)###  WHERE TO BUY

Więcej

 ](https://www.roger.pl/index.php?Itemid=525)

 [ ![](https://www.roger.pl/images/ikony-oferta/cennik.svg)###  Download

Więcej

 ](https://www.roger.pl/index.php?Itemid=544)

 [ ![](https://www.roger.pl/images/ikony-oferta/kontakt.svg)###  Contact us

Więcej

 ](https://www.roger.pl/index.php?Itemid=523)